| Home | Our History | Contact Us | Order Test Kits | Taking Samples | Sample Results | FAQ's | News | Glossary |

Sample Test Results

Thorstensen Laboratory, Inc.
66 Littleton Road, Westford, MA 01886
Tel. (978) 692-8395, Fax (978) 692-0023, 1-800-649-TEST
Report Number: C-49237
Client:

Bill Smith
212 Pondview Road
Westford, MA 01886

Sample taken by: Client

Report Date: August 7th 2000
Sample taken at:

212 Pondview Road
Westford, MA

On: 8/3/2000

 

Certificate of Analysis

TEST PARAMETER               EPA MAX           RESULTS            UNITS
Total Coliform (P)                  0                0          per 100 ml
Arsenic (P)                      0.05            0.006             mg/L
Calcium                      No Limit              0.4             mg/L
Copper (S)                        1.3            <0.02             mg/L
Iron (S)                          0.3            <0.01             mg/L
Lead (P)                        0.015           <0.001             mg/L
Magnesium                    No Limit             <0.1             mg/L
Manganese (S)                    0.05            <0.01             mg/L
Potassium                    Not Spec.             1.1             mg/L
Sodium                            "28            '98.8             mg/L
Alkalinity (S)               Not Spec.           105.0             mg/L
Ammonia                      Not Spec.           <0.03             mg/L
Chloride (S)                      250             48.7             mg/L
Chlorine                     Not Spec.             102             mg/L
Color (S)                          15                0              CPU
Conductivity                 Not Spec.             444         umhos/cm
Fluoride (S)                      4.0              0.9             mg/L
Hardness                     No Limit               <2             mg/L
Nitrates (asN)(P)                  10              0.3             mg/L
Nitrites (as N)(P)                  1            <0.01             mg/L
pH (S)                        6.5-8.5              7.4              SU
Odor (S)                            3                0              TON
Sulphates (S)                     250             31.3             mg/L
Turbitity                    Not Spec.            <0.1              NTU
Sediment                      pos/neg              neg

NT = Not tested, # = Value Exceeds EPA STD, TNTC = To Numerous To Count
* =Backround Bacteria Noted, " = EPA Advisory Limit, ' = Exceedes Advisory Limit
(P) = Primary EPA Standard, (S) = Secondary EPA Standard (may affect aesthetics of
Drinking Water, i.e. taste, color, etc.) ! = E. coli present

This water sample, as submitted, meets EPA requirements for the parameters listed above.
The quality of this water is accepted as POTABLE according to EPA Standards.

 
Massachusetts State Certified
Testing Laboratory #MA048
Michael P. Carlson, for
Thorstensen Laboratory, Inc.

| Home | Our History | Contact Us | Order Test Kits | Taking Samples | Sample Results | FAQ's | News | Glossary |
Copyright © Thorstensen Labs, Inc.
Web Design by: Martin Computing Co.